Instrument Highlights and Features


Features and Benefits

LED light ring illuminates the furnace area

Choice of either argon or helium carrier gas

Novel electrode design increases heat transfer efficiency for increased stability

Non-touch interface systems are also available

User-friendly brand software



High-Performance Detector Design

Thermostatic construction provides increased protection from ambient temperature fluctuations

Optimized emitter control and detection circuitryimproves the IR cell lifetime and long-term stability,

resulting in superior accuracy and precision

Infrared detection for the determination of oxygen, thermoconductivity detection for the determination

of nitrogen




Cornerstone氧氮氢分析软件分成4个主要部分:分析、诊断、设定、仪器,界面可快速导航和组织。山西专业分析仪优惠价格

Procedure - Solid Samples

Instrument calibration/drift correction.

Add approximately 0.05 g of *** Graphite Powder to a *** Graphite Crucible.

Firmly place the crucible on the lower electrode tip or appropriate autoloader position.

Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.

Repeat steps 3b through 3j a minimum of three times for each calibration/drift standard used.

Calibrate/drift following the procedure outlined in the operator's instruction manual.


山西氧氮氢分析仪通用下电极坩埚支座,容纳各种坩埚使用。

氧氮氢分析仪的常见故障及解决方法

仪器启动时显示。没有水流。系统分析电流切断,分析停止。这是水流探测器不正常,水泵不工作,管道堵塞。将仪器的右面板取下,观察水流探测器,用手挤压补水塑料水瓶,发现水流正常,显示正常,证明水流探测器正常,管道畅通。启动循环水泵,但分析仪显示没有水流,此时可判定水泵不正常。打开水泵转子密封口,启动泵发现电机正常运转,此时关闭进水,拆下水泵,发现叶轮脱落。经了解,判定是由于外部冷却水停水,仪器内循环水温过高(水温应≤70℃),致使叶轮(叶轮材料PVC)热胀并脱轴。用粘合剂粘合叶轮后再粘于叶轮轴上,待粘合剂凝固后试车,仪器运行正常。

Determine the instrument blank.

a. Login a minimum of 3 Blank replicates.

b. Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open.

c. Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.

d. Clean the upper and lower electrode manually, or, if applicable, remove thecrucible and press the analyze button to clean with the automatic cleaner.

e. Firmly place a graphite crucible on the lower electrode tip.

f. Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and endautomatically.

g. Repeat steps 2b through 2f a minimum of three times.

h. Set the blank following the procedure outlined in the operator's instruction manual.


长寿命的红外发射光源和无漂移的电路设计保证红外检测池的长期稳定性。

736 Series: Oxygen/Nitrogen by Inert Gas Fusion


The 736 family of Elemental Analyzers is designed for routine measurement of oxygen and nitrogen content of

inorganic materials, ferrous and nonferrous alloys, andrefractory materials using the inert gas fusion technique.

These instruments feature our Cornerstone brand ® software, a custom interface designed specifically for

touch-screen operation. Developed by combining longterm research with customer feedback, this easy-to-use

software gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space.


无需人工干预的全自动清扫系统。山西专业分析仪价格

为可**的Cornerstone 氧氮氧分析软件采用触摸屏界面使用户达到分析控制、15法设定、在线诊断、数据报告。山西专业分析仪优惠价格

Sample Preparation


Sampling and sample preparation is an important issue because traditional methods used to obtain samples for oxygen and nitrogen determination are different from those recommended for hydrogen, especially when sampling molten metal. The main difference in steel sampling procedures for oxygen/nitrogen and hydrogen is due to the mobilityof hydrogen. Special precautions must be used when sampling for hydrogen. From molten steel and iron, a sample must be quickly quenched in cold water and chilled in a refrigerant such as liquefied nitrogen or a mixture of acetone and solid carbon dioxide in order to reduce losses of hydrogen from diffusion. Losses of oxygen and nitrogen from diffusion are not a problem. A sample that is taken for hydrogen and

chilled in a refrigerant can also be used for oxygen and nitrogen determination. However, a sample that is typically taken for oxygen and/or nitrogen determination is not suitable for hydrogen determination due to hydrogen loss (diffusion). Surface contamination must be removed by filing or light grinding, using care not to overheat the sample.